EQUILON ENTERPRISES LLC -- TELLUS(R) OIL 32 -- 9150-01-336-6589
=====================  Product Identification  =====================

Product ID:TELLUS(R) OIL 32
MSDS Date:01/04/1999
FSC:9150
NIIN:01-336-6589
Status Code:A
=== Responsible Party ===
Company Name:EQUILON ENTERPRISES LLC
Address:PRODUCT STEWARDSHIP
Box:674414
City:HOUSTON
State:TX
ZIP:77267-4414
Country:US
Info Phone Num:877-276-7285
Emergency Phone Num:877-276-7283
Resp. Party Other MSDS Num.:EQ MSDS: 60050-12 T
Preparer's Name:KAREN G. HAYNES
Chemtrec Ind/Phone:(800)424-9300
CAGE:3N254
=== Contractor Identification ===
Company Name:AMERICAN INK AND OIL CORP
Address:33 ENDICOTT STREET
Box:City:NORWOOD
State:MA
ZIP:02062-3006
Country:US
Phone:781-762-0026 / FAX: 781-762-1617
Contract Num:SP0450-01-M-LL87
CAGE:82956
Company Name:EQUILON ENTERPRISES LLC PRODUCT STEWARDSHIP
Address:1111 BAGBY RD RM 4325D
Box:674414
City:HOUSTON
State:TX
ZIP:77267-4414
Country:US
Phone:877-276-7285
CAGE:3N254

=============  Composition/Information on Ingredients  =============

Ingred Name:HIGHLY REFINED PETROLEUM OILS (MAY CONTAIN: 64742-54-7,
    64742-65-0)
Minumum % Wt:98.
Maxumum % Wt:99.
Other REC Limits:NOT PROVIDED
OSHA PEL:NOT PROVIDED
ACGIH TLV:NOT PROVIDED

Ingred Name:ADDITIVES
Minumum % Wt:1.
Maxumum % Wt:2.
Other REC Limits:NOT PROVIDED
OSHA PEL:NOT PROVIDED
ACGIH TLV:NOT PROVIDED

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NOT AVAILABLE
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:EYE CONTACT: BASED ON COMPONENT
    INFORMATION, PRODUCT IS PRESUMED TO BE PRACTICALLY NON-IRRITATING.
    SKIN CONTACT: BASED ON COMPONENT INFORMATION, PRODUCT IS PRESUMED
    TO BE	       PRACTICALLY NON- IRRITATING. PROLONGED AND
    REPEATED CONTACT MAY RESULT IN SKIN DISORDERS SUCH AS DERMATITIS.
    OIL ACNE/FOLLICULITIS. ACCIDENTAL RELEASE UNDER HIGH PRESSURE
    APPLICATIONS MAY RESULT IN INJECTION OF OIL IN TO SKIN CAUSING
    LOCAL NECROSIS. INHALATION: VAPORS (GENERATED AT HIGH TEMPERATURES
    ONLY)/OIL MIST MAY CAUSE A MILD IRRITATION OF UPPER RESPIRATORY
    TRACT. INGESTION: PRODUCT IS NO MORE THAN SLIGHTLY TO XIC IF
    SWALLOWED.
Explanation of Carcinogenicity:THIS PRODUCT AND ITS COMPONENTS ARE NOT
    CLASSIFIED AS CARCINOGENS BY    INTERNATIONAL AGENCY FOR RESEARCH
    ON CANCER (IARC), NATIONAL TOXICOLOGY    PROGRAM (NTP) OR
    OCCUPATIONAL SAFETY AND HEALTH ADMIN ISTRATION (OSHA).
Effects of Overexposure:IRRITATION AS NOTED ABOVE.  NECROSIS MAY BE
    EVIDENCED BY		       DELAYED ONSET OF PAIN AND TISSUE
    DAMAGE A FEW HOURS			     FOLLOWING HIGH PRESSURE
    INJECTION.
Medical Cond Aggravated by Exposure:PREEXISTING SKIN AND RESPIRATORY
    DISORDERS MAY BE AGGRAVATED BY EXPOSURE TO

=======================  First Aid Measures  =======================

First Aid:EYE CONTACT: FLUSH WITH WATER. IF IRRITATION OCCURS, GET
    MEDICAL ATTENTION. SKIN CONTACT: REMOVE CONTAMINATED
    CLOTHING/SHOES. WIPE EXCESS FROM SKIN. FLUSH SKIN WITH WATER. 
    FOLLOW BY WASHING WITH SOAP  AND WATER. IF IRRITATION OCCURS, GET
    MEDICAL ATTENTION. IF INJECTED UNDER SKIN, GET MEDICAL ATTENTION
    PROMPTLY. DO NOT WAIT FOR SYMPTOMS TO DEVELOP.  INHALATION: REMOVE
    TO FRESH AIR AND PROVIDE OXYGE N IF BREATHING IS DIFFICULT. GET
    MEDICAL ATTENTION. INGESTION: DO NOT INDUCE VOMITING.  IN GENERAL,
    NO TREATMENT IS NECESSARY		   UNLESS LARGE QUANTITIES OF
    PRODUCT ARE INGESTED.  HOWEVER, GE T MEDICAL ADVICE.

=====================  Fire Fighting Measures  =====================

Flash Point Method:PMCC
Flash Point:=193.3C, 380.F
Lower Limits:N/AV
Upper Limits:N/AV
Extinguishing Media:USE WATER FOG, FOAM, DRY CHEMICAL OR CO2.  DO NOT
    USE A DIRECT STREAM OF
Fire Fighting Procedures:MATERIALS WILL NOT BURN UNLESS PREHEATED.  DO
    NOT ENTER CONFINED FIRE SPACE    WITHOUT FULL BUNKER GEAR (HELMET
    WITH FACE SHIELD, BUNKER COATS, GLOVES AND	  RUBBER BOOTS),
    INCLUDING A POSITIVE PRESSU RE NIOSH APPROVED SELF-CONTAINED   
    BREATHING APPARATUS.  COOL FIRE EXPOSED CONTAINERS WITH WATER.
Unusual Fire/Explosion Hazard:NONE IDENTIFIED.

==================  Accidental Release Measures  ==================

Spill Release Procedures:LARGE SPILLS: WEAR RESPIRATOR AND PROTECTIVE
    CLOTHING AS APPROPRIATE.  SHUT OFF SOURCE OF LEAK IF SAFE TO DO SO.
     DIKE AND CONTAIN.	REMOVE WITH VACUUM TRUCKS OR PUMP TO
    STORAGE/SALVAGE VESSELS.  SOAK  UP RESIDUE WITH AN ABSORBENT SUCH
    AS CLAY, SAND OR OTHER SUITABLE MATERIAL; DISPOSE OF PROPERLY. 
    FLUSH AREA WITH WATER TO REMOVE TRACE RESIDUE. SMALL SPILLS: TAKE
    UP WITH AN ABSORBENT MATERIAL.
Neutralizing Agent:NOT RELEVANT

======================	Handling and Storage  ======================

Handling and Storage Precautions:STORE IN A COOL, DRY PLACE WITH
    ADEQUATE  VENTILATION.  KEEP AWAY FROM OPEN FLAMES AND HIGH
    TEMPERATURES.
Other Precautions:MINIMIZE SKIN CONTACT.  WASH WITH SOAP AND WATER
    BEFORE EATING, DRINKING,  SMOKING OR USING TOILET FACILITIES. 
    LAUNDER CONTAMINATED CLOTHING BEFORE  REUSE.  PROPERLY DISPOSE OF
    CONTAMINATED LEATHER A RTICLES, INCLUDING SHOES,  THAT CANNOT BE
    DECONTAMINATED.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:IF EXPOSURE MAY OR DOES EXCEED OCCUPATIONAL
    EXPOSURE LIMITS (SEC. IV) USE A    NIOSH-APPROVED RESPIRATOR TO
    PREVENT OVEREXPOSURE.  IN ACCORD WITH 29 CFR    1910.134 USE EITHER
    AN ATMOSPHERE-SUPPLYING  RESPIRATOR OR AN AIR-PURIFYING   
    RESPIRATOR FOR ORGANIC VAPORS AND PARTICULATES.
Ventilation:NONE IDENTIFIED
Protective Gloves:NITRILE GLOVES.
Eye Protection:NO SPECIAL EYE PROTECTION IS ROUTINELY NECESSARY.
Other Protective Equipment:WEAR PROTECTIVE CLOTHING AS REQUIRED TO 
    MINIMIZE SKIN CONTACT.
Work Hygienic Practices:NONE IDENTIFIED
Supplemental Safety and Health
ABBREVIATION: N/A = NOT APPLICABLE. N/AV = NOT AVAILABLE. N/K =
    UNKNOWN. N/P = NOT PROVIDED. N/R = NOT RELEVANT. N/D = NOT
    DETERMINED. N/E = NOT ESTABLISHED. CNS = CENTRAL NERVOUS SYSTEM. GI
    = GASTROI NTESTINAL. SCBA = SELF CONTAINED BREATHING APPARATUS.

==================  Physical/Chemical Properties  ==================

HCC:V6
NRC/State Lic Num:NOT RELEVANT
Melt/Freeze Pt:=-28.7C, -20.F
M.P/F.P Text:POUR POINT
Decomp Temp:Decomp Text:NOT PROVIDED
Vapor Pres:<0.1
Vapor Density:N/AV
Spec Gravity:0.8676
Viscosity:32 CS @ 104 DEG F
Evaporation Rate & Reference:NOT AVAILABLE
Solubility in Water:NEGLIGIBLE
Appearance and Odor:YELLOW LIQUID. SLIGHT HYDROCARBON ODOR.
Corrosion Rate:NOT PROVIDED

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
OXIDIZING MATERIALS.
Stability Condition to Avoid:HEAT, OPEN FLAMES.
Hazardous Decomposition Products:A COMPLEX MIXTURE OF AIRBORNE SOLID,
    LIQUID PARTICULATES AND GASES EVOLVE WHEN MATERIAL UNDERGOES
    PYROLYSIS/COMBUSTION. CARBON MONOXIDE AND UNIDENTIFIED ORGANIC
    COMPOUNDS MAY BE FORMED UPON COMBUSTION.

===================  Toxicological Information	===================

Toxicological Information:NOTE TO PHYSICIAN:  IN GENERAL, EMESIS
    INDUCTION IS UNNECESSARY IN HIGH VISCOSITY, LOW VOLATILITY
    PRODUCTS, I.E., MOST OILS AND GREASES.

=====================  Ecological Information  =====================

Ecological:NOT PROVIDED

====================  Disposal Considerations  ====================

Waste Disposal Methods:IF THIS PRODUCT BECOMES A WASTE, IT WOULD NOT BE
    A HAZARDOUS WASTE BY RCRA	 CRITERIA (40 CFR 261).  PLACE IN AN
    APPROPRIATE DISPOSAL FACILITY IN	COMPLIANCE WITH LOCAL
    REGULATIONS.

=====================  Regulatory Information  =====================

SARA Title III Information:NO.	EHS RQ	 EHS TPQ  SEC-313  313 CATEGORY
		311/312 CATEGORY	(*1)	  (*2)	  (*3)	     
    (*4)		       (*5) 
    ========================================================
    =======================  BASED ON THE DATA AVAILABLE, THIS PRODUCT
    IS NOT REGULATED BY SARA,TITLE III. SUBSTANCES PROTECTION OF
    STRATOSPHERIC OZONE (PURSUANT TO SECTION 611 OF THE CLEAN AIR ACT 
    AMEND MENTS OF 1990):  PER 40 CFR PART 82, THIS PRODUCT DOES NOT
    CONTAIN NOR WAS  IT DIRECTLY MANUFACTURED WITH ANY CLASS I OR CLASS
    II OZONE DEPLETINGSUBSTANCES.
Federal Regulatory Information:THE COMPONENTS OF THIS PRODUCT ARE
    LISTED ON THE EPA/TSCA INVENTORY OF CHEMICAL  SUBSTANCES. THIS
    PRODUCT IS AN OIL UNDER 49 CFR (DOT) PART 130.  IF SHIPPED BY RAIL
    OR	  HIGHWAY IN A TANK WITH A CAPA CITY OF 3,500 GALLONS OR MORE,
    IT IS SUBJECT TO	THE REQUIREMENTS OF PART 130.  MIXTURES OR
    SOLUTIONS IN WHICH THIS PRODUCT IS	  PRESENT AT 10% OR MORE MAY
    ALSO BE SUBJECT TO THIS RULE.
State Regulatory Information:BASED ON INFORMATION AVAILABLE, THIS
    PRODUCT DOES NOT CONTAIN ANY CHEMICAL SUBSTANCE REGULATED BY A
    SPICIFIC STATE LIST.

=======================  Other Information  =======================

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.