UNION CARBIDE CORPORATION -- ARGON -- 6830-00-167-0778
=====================  Product Identification  =====================

Product ID:ARGON
MSDS Date:12/01/1986
FSC:6830
NIIN:00-167-0778
=== Responsible Party ===
Company Name:UNION CARBIDE CORPORATION
Address:39 OLD RIDGEBURY ROAD
City:DANBURY
State:CT
ZIP:06817-0001
Country:US
Emergency Phone Num:1-800-822-4357 CANADA 514-640-6400
CAGE:36346
=== Contractor Identification ===
Company Name:HAMPTON ROADS SUPPLY UNION CARBIDE LINDE DIVISION
Address:3450 VIRGINIA BEACH BLVD
Box:12567
City:NORFOLK
State:VA
ZIP:23502-3123
Country:US
CAGE:7D711
Company Name:UNION CARBIDE CORP   LINDE DIV
Address:39 OLD RIDGEBURY RD
Box:City:DANBURY
State:CT
ZIP:06817-0001
Country:US
Phone:800-822-4357; 304-744-3487
CAGE:36346

=============  Composition/Information on Ingredients  =============

Ingred Name:ARGON
CAS:7440-37-1
Fraction by Wt: 100%

=====================  Hazards Identification  =====================

Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:NO
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:FUMES AND GASES CAN BE DANGEROUS TO
    YOUR HEALTH AND MAY CAUSE LUNG DISEASE.SHORTTERM OVEREXPOSURE TO
    FUMES MAY RESULT IN DISCOMFORT SUCH AS DIZZINESS, NAUSEA,ORDRYNESS
    OR IRRITATION OF NOSE, THROAT, O R EYES. SOME TOXIC GASES
    ASSOCIATED WITHWELDING & RELATED PROCESSES MAY CAUSE PULMONARY
    EDEMA, ASPHYXIATION, AND DEATH.
Effects of Overexposure:ASPHYXIANT. MODERATE CONCENTRATIONS MAY CAUSE
    HEADACH, DROWSINESS, DIZZINESS,   EXCITATION, EXCESS SALIVATINO,
    VOMITING, AND UNCONSCIOUSNESS. ARGON IS AN ASPHY-XIANT. LACK OF
    OXYGEN CAN CAUSE DEATH. F UMES AND GASES CAN BE DANGEROUS TO
    YOURHEALTH AND MAY CAUSE SERIOUS LUNG DISEASE.

=======================  First Aid Measures  =======================

First Aid:SKIN/EYE CONTACT: FLUSH WITH WATER.  INHILATION: REMOVE TO
    FRESH AIR. GIVE CPR  IF NOT BREATHING AND OXYGEN IF BREATHING IS
    DIFFICULT. CALL A PHYSICIAN.

=====================  Fire Fighting Measures  =====================

Extinguishing Media:STOP FLW OF GAS W/O RISK WHILE CONT WTR SPRAY.ALLOW
    FIRE TO BRN OUT.ON SITE FIRE BRIGADES MUST COMPLY W/OSHA29CFR1910
Fire Fighting Procedures:EVACUATE ALL PERSONNEL FROM DANGER AREA. 
    IMMED. COOL CYL. WITH WATER SPRAY FROMMAX DISTANCE, THEN MOVE
    CONTAINERS AWAY FROM FIRE AREA IF W/O RISK.SHUT LEAK OFF
Unusual Fire/Explosion Hazard:ARGON CANNOT CATCH FIRE. CONTAINER MAY
    RUPTURE DUE TO HEAT OF FIRE. NO PART OF  CONTAINER SHOULD BE
    SUBJECTED TO A TEMP HIGHER THAN 125F/52C.

==================  Accidental Release Measures  ==================

Spill Release Procedures:EVACUATE ALL PERSONNEL FROM DANGER AREA. USE
    SELF CONTAINED BREATHING APPARATUS WHERE NEEDED. SHUT  OFF CYLINDER
    IF W/O RISK. VENT AREA OF LEAK OR MOVCYL TO WELL VENTILATED AREA.
    TEST AREA FOR SUFFICI OXY CONTENT PRIOR TO PERMITTING RE-ENTRY.

======================	Handling and Storage  ======================

Handling and Storage Precautions:PREVENT FIRES. STORE/USE WITH ADEQUATE
    VENTILATIONTHE DEFECT PRODUCED BY AN ARC BURN COULD LEAD TO 
    CYLINDER RUPTURE. DO NOT GROUND CYLINDER.
Other Precautions:SEE NFPA 51B

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:USE RESPIRABLE FUME RESPIRATOR OR AIR SUPPLIED
    RESPIRATOR WHEN WORKING IN CON-  FINED SPACE OR WHERE LOCAL EXHAUST
    OR VENTILATION DOES NOT KEEP EXPOSURE BELOW  TLV.
Ventilation:USE ENOUGH VENTILATION, LOCAL EXHAUST OR BOTH, TO KEEP
    FUMES& GASES BELOW TLV'S IN THE WORKERS BREATHING ZONE & AREA.
Protective Gloves:WELDING GLOVES
Eye Protection:WEAR HELMET OR USE FACE SHIELD
Other Protective Equipment:AS NEEDED, WEAR HAND, HEAD,AND BODY
    PROTECTION WHICH HELP TOPREVENT INJURY FROM RADIATION, SPARKS, &
    ELECTRICAL SHOCK.
Supplemental Safety and Health
WHEN TWO OR MORE GASES, OR LIQUEFIED GASES ARE MIXED, THEIR HAZARDOUS
    PROPERTIESMAY COMBINE TO CREATE ADDITIONAL, UNEXPECTED HAZARDS.

==================  Physical/Chemical Properties  ==================

Boiling Pt:B.P. Text:-185C/-302F
Vapor Pres:GAS
Vapor Density:*SEE BELOW
Spec Gravity:GAS
Solubility in Water:NEGLIBLE
Appearance and Odor:COLORLESS, ODORLESS GAS AT NORMAL TEMPERATURE AND
    PRESSURE.
Percent Volatiles by Volume:100

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
NK *VAP DENS: 1.378 @ 21.2C/70F
Stability Condition to Avoid:HIGH PRESSURE GAS. CLOSE VALVE WHEN NOT IN
    USE & WHEN EMPTY.USE WITH EQUIP RATED TO WITHSTAND PRESSURE.DON'T
    GROUND CYL.
Hazardous Decomposition Products:OZONE & NITROGEN OXIDES MAY BE FORMED
    BY THE RADIATION FROM ARC.

====================  Disposal Considerations  ====================

Waste Disposal Methods:SLOWLY RELEASE INTO ATMOSPHERE. DISCARD ANY
    PRODUCRESIDUE, DISPOSABLE CONTAINER OR LINER IN AN ENVIRONMENTALLY
    ACCEPTABLE MANNER IN FULL COMPLIANCE   WITH FEDERAL, STATE AND
    LOCAL REGULATIONS.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.