RALMIKE'S TOOL-A-RAMA -- MICROFINISH -- 6850-00N006965
=====================  Product Identification  =====================

Product ID:MICROFINISH
MSDS Date:01/01/1987
FSC:6850
NIIN:00N006965
=== Responsible Party ===
Company Name:RALMIKE'S TOOL-A-RAMA
Emergency Phone Num:201-561-6680
CAGE:51142
=== Contractor Identification ===
Company Name:RALMIKE'S TOOL-A-RAMA
CAGE:51142

=============  Composition/Information on Ingredients  =============

Ingred Name:METHYL CHLOROFORM (1,1,1-TRICHLOROEHANE)  (SARA III)
CAS:71-55-6
RTECS #:KJ2975000
Fraction by Wt: < 25%
OSHA PEL:350 PPM/450 STEL
ACGIH TLV:350 PPM/450STEL;9192
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
Ozone Depleting Chemical:1

Ingred Name:PETROLEUM HYDROCARBON PROPELLANT
Fraction by Wt: < 15%
ACGIH TLV:1,000 PPM (MFR)

Ingred Name:ODORLESS MINERAL SPIRITS (CAS# 64742-88-7)
Fraction by Wt: < 10%
ACGIH TLV:500 PPM (MFR)

=====================  Hazards Identification  =====================

Effects of Overexposure:EYES:IRRIT,RED,TEAR,BLUR
    VISION.SKIN:IRRIT,DEFAT,DERMATITIS.INHAL:NASAL,RESP IRRIT,DIZZ(SEE
    SUPP DAT

=======================  First Aid Measures  =======================

First Aid:EYES:FLUSH W/PLENTY OF H*2O FOR 15 MIN.CALL DR.SKIN:WASH
    W/SOAP,H*2O.RMV CONTAM CLTHG,WASH BEFORE REUSE.INHAL:RMV TO FRESH
    AIR.IF BRTHG DIFF GIVE O*2.IF STOP BRTHG GIVE ARTF RESP.KEEP
    WARM,QUIET.CALL  DR.DONT GIVE STIMULANT.INGEST:DONT (SEESUPP DATA)

=====================  Fire Fighting Measures  =====================

Flash Point:170F(76.7C),CCC
Lower Limits:6.7
Extinguishing Media:CO*2,FOAM,DRY CHEMICALS.
Fire Fighting Procedures:PRESS DEMAND SCBA,FULL PROT CLTHG.COOL
    FIRE-EXP CNTNR W/H*2O
Unusual Fire/Explosion Hazard:THERMAL DECOMPOSITION PROD MAY INCLUDE
    HCL,PHOSGENE,CO*2,CO,TOXIC MATERIALS,VARIOUS HYDROCARBONS.

==================  Accidental Release Measures  ==================

Spill Release Procedures:SM SPILL:ABSORB ON ABSORBENT MATL.MOVE TO
    HOOD.LGE SPILL:ELIMINATE IGNIT SOURCES.EVACUATE AREA,USE PROT
    EQUIP.STOP SPILL @ SOURCE,DIKE AREA,PUMP LIQ TO SALVAGE TANK.ABSORB
    ON EARTH/ABSORBENT MATL,SHOV EL INTO CNTNR.PVNT RUNOFF,NOTIFY AUTH
    IF OCCURS.

======================	Handling and Storage  ======================

Handling and Storage Precautions:CNTNRS POSS HAZ WHEN EMPTIED,OBSERVE
    ALL HAZ PRECAUT IN MSDS.OVEREXP TO MATL SUGGESTED AS CAUSE OF
    CARDIAC & LIVER ABNORMALITY,KIDNEY & LUNG DAMAGE.
Other Precautions:NO SMKING IN AREA.DONT USE IN GENL VICINITY OF ARC
    WELDG,OPEN FLM/HOT SURF.HEAT/UV RADIATION POSS HCL/PHOSGENE FORMED.
    BALANCE OF FORMULA IS TRADE SECRET.INFO AVAILABLE UPON REQUEST FROM
    MFR.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:NIOSH/MSHA APPROVED RESP PROT DEPENDING ON
    CONDITION OF USE.
Ventilation:SUFFICIENT MECH(GENL &/OR LOCAL EXH) VENT TO KEEP BELOW
    TLV.
Protective Gloves:POLYETHYLENE
Eye Protection:CHEM SPLASH GOGGLES
Other Protective Equipment:IMPERVIOUS CLOTHING & BOOTS.POLYVINOL
    ALCOHOL GLOVES
Supplemental Safety and Health
OVEREXP
    EFT:WEAK,FATG,NAUS,UNCONSCIOUS,ASPHYXIATION.INGEST:GASTROINTESTINE
    IRRIT,NAUS,VOMIT,DIARR.FIRST AID:INDUCE VOMIT,POSS CHEM PNEUMONITIS
    IF ASPIRATE IN LUNGS.KEEP WARM,QUIET.CALL DR.

==================  Physical/Chemical Properties  ==================

Boiling Pt:B.P. Text:165F(73.9C)
Vapor Density:>1
Spec Gravity:>1
Evaporation Rate & Reference:GREATER THAN ETHER
Solubility in Water:NEGLIGIBLE
Appearance and Odor:LIGHT AMBER,CHLORINATED HYDROCARBON ODOR.
Percent Volatiles by Volume:<35

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING & REDUCING AGENTS,STRONG ALKALI.
Hazardous Decomposition Products:CO,CO*2,HCL,PHOSGENE,INCOMPLETE BURNED
    HYDROCARBON PRODUCTS.

====================  Disposal Considerations  ====================

Waste Disposal Methods:SM SPILL:ALLOW TO EVAPORATE IN HOOD.WAIT TILL
    VAP CLEAR HOOD DUCT WORK.DISPOSE OF REMAINING MATL IAW
    FEDERAL,STATE & LOCAL REGULATIONS.LGE SPILL:LIQUID
    INCINERATION,CONTAM ABSORBENT DEPOSITED IN LANDF ILL IAW
    FEDERAL,STATE & LOCAL REGULATIONS.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.