XEROX CORP XEROX SQ 010A -- 8R3903 XEROX FUSER AGENT (5046) -- 6850-01-414-3520
=====================  Product Identification  =====================

Product ID:8R3903 XEROX FUSER AGENT (5046)
MSDS Date:03/04/1996
FSC:6850
NIIN:01-414-3520
=== Responsible Party ===
Company Name:XEROX CORP XEROX SQ 010A
Address:100 CLINTON AVE S
City:ROCHESTER
State:NY
ZIP:14644-1877
Country:US
Info Phone Num:800-828-6571
Emergency Phone Num:716-422-2177
CAGE:6U221
=== Contractor Identification ===
Company Name:TONER ETC
Address:210 WEST RD
Box:City:PORTSMOUTH
State:NH
ZIP:03801
Country:US
Phone:800-370-8683
CAGE:0NU41
Company Name:XEROX CORP XEROX SQ 010A
Address:100 CLINTON AVE S
City:ROCHESTER
State:NY
ZIP:14644-1877
Country:US
Phone:716-422-2177
CAGE:6U221
Company Name:XEROX CORPORATION
Address:100 CLINTON AVE SOUTH
Box:City:ROCHESTER
State:NY
ZIP:14644-1877
Country:US
Phone:800-828-6571/716-422-2177
CAGE:26921

=============  Composition/Information on Ingredients  =============

Ingred Name:POLY (DIMETHYLSILOXANE)
CAS:63148-62-9
RTECS #:JJ6484500
Fraction by Wt: 85-95%
Other REC Limits:NONE RECOMMENDED

Ingred Name:ORGANO-FUNCTIONAL POLYDIMETHYLSILOXANE, CAS #108775-26-4
    (TSCA)/67923-16-4).
Fraction by Wt: 5-15%
Other REC Limits:NONE RECOMMENDED

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:LD50 (ORAL, RAT)=>35G/KG.
Routes of Entry: Inhalation:YES  Skin:NO  Ingestion:NO
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:MAY CAUSE MINIMAL IRRITATION OF
    RESPIRATORY PASSAGES ON CONTINOUS EXPOSURE TO HIGH CONCENTRATIONS.
Explanation of Carcinogenicity:PER MSDS NO CARCINOGENS PRESENT.
Effects of Overexposure:NONE SPECIFIED BY MANUFACTURER.
Medical Cond Aggravated by Exposure:NONE.

=======================  First Aid Measures  =======================

First Aid:EYE: FLUSH THOROUGHLY WITH WATER. SKIN: WASH WITH SOAP &
    WATER. INHALATION: REMOVE FROM EXPOSURE. INGESTION: DILUTE STOMACH
    CONTENTS WITH SEVERAL GLASSES OF WATER.

=====================  Fire Fighting Measures  =====================

Flash Point Method:PMCC
Flash Point:>500F,>260C
Extinguishing Media:FOAM, CARBON DIOXIDE, WATER SPRAY.
Fire Fighting Procedures:WEAR SELF-CONTAINED BREATHING APPARATUS &
    PROTECTIVE CLOTHING.
Unusual Fire/Explosion Hazard:NONE.

==================  Accidental Release Measures  ==================

Spill Release Procedures:CLEAN THOROUGHLY AS RESIDUE IS SLIPPERY. SOAK
    UP WITH AN ABSORBENT MATERIAL. PLACE IN APPROPRIATE CHEMICAL WASTE
    CONTAINER. FLUSH SPILL AREA WITH WATER.
Neutralizing Agent:NOT APPLICABLE.

======================	Handling and Storage  ======================

Handling and Storage Precautions:USE REASONABLE CARE AND CAUTION. STORE
    IN COOL, DRY, WELL-VENTILATED AREA. CLEAN UP SPILLS COMPLETELY AS
    RESIDUE IS SLIPPERY.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:NONE REQUIRED WHEN USED AS INTENDED IN XEROX
    EQUIPMENT.
Ventilation:NONE SPECIFIED BY MANUFACTURER.
Protective Gloves:NONE REQUIRED WHEN USED AS INTENDED.
Eye Protection:NONE REQUIRED WHEN USED AS INTENDED.
Other Protective Equipment:NONE REQUIRED WHEN USED AS INTENDED IN XEROX
    EQUIPMENT.
Work Hygienic Practices:WASH HANDS AFTER HANDLING PRODUCT.
Supplemental Safety and Health
PART NOS:8R882; 8R1288; 8R2944; 8R2945; 8R2955; 8R3808; 8R3840; 8R3903;
    RX:8R90163.

==================  Physical/Chemical Properties  ==================

HCC:N1
Boiling Pt:B.P. Text:NON-VOLATIL
Vapor Pres:<0.1 @68F
Spec Gravity:0.96
VOC Pounds/Gallon:960
Evaporation Rate & Reference:<1 (ETHER=1)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:CLEAR LIQUID, SLIGHT ODOR
Percent Volatiles by Volume:<1

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:NONE.
Hazardous Decomposition Products:SILICONE DIOXIDE, CARBON DIOXIDE,
    CARBON MONOXIDE, FORMALDEHYDE AND TRACES OF INCOMPLETELY BURNED
    CARBON PRODUCTS.

====================  Disposal Considerations  ====================

Waste Disposal Methods:ABSORB LIQUID ON VERMICULITE OR OTHER ABSORBENT
    MATERIAL. DISPOSE OF IN ACCORDANCE WITH LOCAL, STATE AND FEDERAL
    REGULATIONS. BIODEGRADATION/NON-BIODEGRADABLE, BIOACCUMULATION/NO
    EVEIDENCE OF ACCUMULA TION.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.