K&N ENGINEERING INC. -- AIR FILTER CLEANER -- 7930-00D020172
=====================  Product Identification  =====================

Product ID:AIR FILTER CLEANER
MSDS Date:06/24/1992
FSC:7930
NIIN:00D020172
=== Responsible Party ===
Company Name:K&N ENGINEERING INC.
Address:561 IOWA AVE
City:RIVERSIDE
State:CA
ZIP:92502
Country:US
Info Phone Num:714-684-9762
Emergency Phone Num:714-684-9762
CAGE:EO398
=== Contractor Identification ===
Company Name:BALKAMP INC
Address:2601 S HOLT ROAD
Box:City:INDIANAPOLIS
State:IN
ZIP:46241
Country:US
Phone:317-244-7241
CAGE:70842
Company Name:K AND N ENGINEERING INC (714-684-9762)
CAGE:0N0N0
Company Name:K&N ENGINEERING INC.
Address:561 IOWA AVE
Box:City:RIVERSIDE
State:CA
ZIP:92502
Country:US
Phone:714-684-9762
CAGE:EO398
Company Name:NAPA, A DIVISION OF LINCOLN AUTOMOTIVE
Address:ONE LINCOLN WAY
Box:City:ST. LOUIS
State:MO
ZIP:63120-1578
Country:US
Phone:414-255-5520
CAGE:050Q3

=============  Composition/Information on Ingredients  =============

Ingred Name:SODIUM METASILICATE
CAS:6834-92-0
RTECS #:VV9275000
Fraction by Wt: 3.5% %
Other REC Limits:NONE RECOMMENDED

Ingred Name:NON-HAZARDOUS INGREDIENTS
Fraction by Wt: BALANCE
Other REC Limits:NONE RECOMMENDED

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NOT GIVEN FOR PRODUCT AS A WHOLE
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:YES
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:INHALATION: MAY CAUSE SLIGHT HEADACHE
    AND/OR DIZZINESS. SKIN CONTACT MAY CAUSE IRRITATION. INGESTION MAY
    CAUSE IRRITATION AND NAUSEA. EYE CONTACT MAY CAUSE IRRITATION.
Explanation of Carcinogenicity:THIS COMPOUND CONTAINS NO INGREDIENTS AT
    CONCENTRATIONS OF 0.1% OR GREATER THAT ARE CARCINOGENS OR SUSPECT
    CARCINOGENS.
Effects of Overexposure:HEADACHE, DIZZINESS, SKIN IRRITATION, GI TRACT
    IRRITATION, NAUSEA, EYE IRRITATION.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

=======================  First Aid Measures  =======================

First Aid:INHALATION: MOVE TO FRESH AIR. IF UNCONSCIOUS, CONTACT
    PHYSICIAN. SKIN: WASH WITH SOAP AND WATER. IF IRRITATION PERSISTS,
    CALL A PHYSICIAN. INGESTION: CALL PHYSICIAN. EYES: FLUSH WITH WATER
    FOR 15 MIN UTES. IF IRRITATION PERSISTS, CALL PHYSICIAN.

=====================  Fire Fighting Measures  =====================

Flash Point:NONFLAMMABLE
Lower Limits:NOT GIVEN
Upper Limits:NOT GIVEN
Extinguishing Media:CARBON DIOXIDE, DRY FOAM
Fire Fighting Procedures:NONFLAMMABLE. USE STANDARD FIREFIGHTING
    PROCEDURES FOR SURROUNDING MATERIALS IN THE FIRE.
Unusual Fire/Explosion Hazard:NONE SPECIFIED BY MANUFACTURER.

==================  Accidental Release Measures  ==================

Spill Release Procedures:SOAK UP WITH AN INERT ABSORBENT. PUT IN A
    CLOSED METAL CONTAINERS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:STORE IN COOL, DRY AREA BELOW 110F,
    OUT OF DIRECT SUNLIGHT.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:NONE REQUIRED UNDER NORMAL CONDITIONS
Ventilation:LOCAL EXHAUST AND MECHANICAL (GENERAL) VENTILATION AS
    REQUIRED TO MAINTAIN EXPOSURE LEVELS.
Protective Gloves:RUBBER OR PLASTIC RECOMMENDED
Eye Protection:SAFETY GLASSES OR GOGGLES
Other Protective Equipment:AN EMERGENCY EYEWASH AND SHOWER SHOULD BE
    AVAILABLE.
Work Hygienic Practices:WASH HANDS THOROUGHLY WITH SOAP AND WATER
    BEFORE EATING, DRINKING, SMOKING OR USING TOILET FACILITIES.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.

==================  Physical/Chemical Properties  ==================

HCC:N1
Boiling Pt:B.P. Text:180F,82C
Melt/Freeze Pt:M.P/F.P Text:NOT GIVEN
Vapor Pres:NOT GIVEN
Vapor Density:NOT GIVEN
Spec Gravity:1.04
Evaporation Rate & Reference:NOT GIVEN
Solubility in Water:COMPLTE
Appearance and Odor:PINK, SOLVENT ODOR

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
ACIDIC MATERIALS
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:NONE SPECIFIED BY MANUFACTURER.

====================  Disposal Considerations  ====================

Waste Disposal Methods:DISPOSE IN ACCORDANCE WITH ALL FEDERAL, STATE
    AND LOCAL REGULATIONS.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.