SEARS, ROEBUCK AND CO -- ANTI-RUST ENAMEL SATIN FLAT BLACK, 66438 -- 8010-00N075753
=====================  Product Identification  =====================

Product ID:ANTI-RUST ENAMEL SATIN FLAT BLACK, 66438
MSDS Date:03/27/1996
FSC:8010
NIIN:00N075753
=== Responsible Party ===
Company Name:SEARS, ROEBUCK AND CO
Address:233 S WACKER DR SEARS TOWER
City:CHICAGO
State:IL
ZIP:60684
Country:US
Info Phone Num:216-566-2902
Emergency Phone Num:216-566-2917
CAGE:53800
=== Contractor Identification ===
Company Name:SEARS ROEBUCK AND CO
Address:233 S WACKER DR
Box:City:CHICAGO
State:IL
ZIP:60684
Country:US
Phone:216-566-2902
CAGE:53800

=============  Composition/Information on Ingredients  =============

Ingred Name:PROPANE VP:760
CAS:74-98-6
RTECS #:TX2275000
Fraction by Wt: 15%
OSHA PEL:1000 PPM
ACGIH TLV:ASPHYXIANT

Ingred Name:BUTANE VP:760
CAS:106-97-8
RTECS #:EJ4200000
Fraction by Wt: 14%
OSHA PEL:800 PPM
ACGIH TLV:00 PPM

Ingred Name:VM & P NAPHTHA VP:12.00
CAS:64742-89-8
Fraction by Wt: 2%
OSHA PEL:300 PPM (MFR)
ACGIH TLV:300 PPM (MFR)

Ingred Name:TOLUENE (SARA 313) (CERCLA) VP:22.00
CAS:108-88-3
RTECS #:XS5250000
Fraction by Wt: 19%
OSHA PEL:200 PPM
ACGIH TLV:S, 50 PPM
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS

Ingred Name:XYLENE (SARA 313) (CERCLA) VP:5.90
CAS:1330-20-7
RTECS #:ZE2100000
Fraction by Wt: 3%
OSHA PEL:100 PPM
ACGIH TLV:100 PPM/150STEL
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS

Ingred Name:ACETONE (SARA 313) (CERCLA) VP:180.00
CAS:67-64-1
RTECS #:AL3150000
Fraction by Wt: 26%
OSHA PEL:1000 PPM
ACGIH TLV:750PPM/1000STEL
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS

Ingred Name:PROPIONIC ACID, 3-ETHOXY-, ETHYL ESTER;
    (ETHYL-3-ETHOXYPROPIONATE). VP:1.11.
CAS:763-69-9
RTECS #:UF3325000
Fraction by Wt: 5%
OSHA PEL:N/K 
ACGIH TLV:N/K 

Ingred Name:TALC (POWDER), CONTAINING NO ASBESTOS FIBERS; (TALC)
CAS:14807-96-6
RTECS #:WW2710000
Fraction by Wt: 6%
OSHA PEL:20 MPPCF Z-3
ACGIH TLV:2 MG/M3 RDUST

Ingred Name:EFTS OF OVEREXP:PRLNGD OVEREXP TO SOLV INGS MAY CAUSE
    ADVERSE EFTS TO LIVER, URINARY, CVS & REPRO SYS. RPTS HAVE(ING 10)
RTECS #:9999999ZZ

Ingred Name:ING 9:ASSOCIATED REPEATED AND PROLONGED OVEREXPOSURE TO
    SOLVENTS WITH PERMANENT BRAIN AND NERVOUS SYSTEM DAMAGE.
RTECS #:9999999ZZ

Ingred Name:OTHER PRECS:CONSULT NFPA CODE. USE APPRVD BONDING &
    GROUNDING PROCEDURES. CONTENTS UNDER PRESS. DO NOT PUNCTURE,(ING
    12)
RTECS #:9999999ZZ

Ingred Name:ING 11:INCIN/EXPOSE TO TEMP ABOVE 120F. HEAT FROM SUNLIGHT,
    RADIATORS, STOVES, HOT WATER, & (ING 13)
RTECS #:9999999ZZ

Ingred Name:ING 12:OTHER HEAT SOURCES COULD CAUSE CNTNR TO BURST. DO
    NOT TAKE INTERNALLY. KEEP OUT OF REACH OF CHILDREN. (ING 14)
RTECS #:9999999ZZ

Ingred Name:ING 13:INTENTIONAL MISUSE BY DELIBERATELY CONCENTRATING AND
    INHALING THE CONTENTS CAN BE HARMFUL OR FATAL.
RTECS #:9999999ZZ

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:NO
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:EXPOS MAY BE BY INHAL &/OR SKIN/EYE
    CONT, DEPENDING ON CNDTNS OF USE. TO MIN EXPOS, FOLLOW RECS FOR
    PROPER USE, VENT, & PERS PROT EQUIP. EFTS:IRRIT OF EYES, SKIN &
    RESP SYS. MAY CAUSE NERV SYS DEPRESS . EXTREME OVEREXP MAY RSLT IN
    UNCON & POSS DEATH. SIGNS & SYMPS:HDCH, DIZZ, NAUS & LOSS OF COORD
    ARE (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZS:INDICATIONS OF EXCESSIVE EXPOS TO
    VAPS/SPRAY MIST. REDNESS & ITCHING/BURNING SENSATION MAY INDICATE
    EYE/EXCESSIVE SKIN EXPOS. CHRONIC:TOLUENE APPEARS ON NAVY OCCUP
    CHEM REPRO HAZS LIST. SEEK	CONSULTATION FROM APPROP HLTH
    PROFESSIONALS CONCERNING LATEST HAZ LIST INFO & SAFE HNDLG & EXPOS
    INFO . (ING 9)
Medical Cond Aggravated by Exposure:NONE GENERALLY RECOGNIZED.

=======================  First Aid Measures  =======================

First Aid:INHAL:REMOVE FROM EXPOSURE. RESTORE BREATHING. KEEP WARM AND
    QUIET. SKIN:WASH AFFECTED AREA THOROUGHLY WITH SOAP AND WATER.
    REMOVE CONTAMINATED CLOTHING AND LAUNDER BEFORE REUSE. EYES:FLUSH
    WITH LARGE	AMOUNTS OF WATER FOR AT LEAST 15 MINUTES. GET MED ATTN.
    INGEST:NEVER GIVE ANYTHING BY MOUTH TO AN UNCON PERSON. DO NOT
    INDUCE VOMIT. GIVE CONSCIOUS PATIENT SEVERAL GLASSES OF WATER. SEEK
    MED ATTN.

=====================  Fire Fighting Measures  =====================

Flash Point Method:TCC
Flash Point:-20F,-29C
Lower Limits:0.9%
Upper Limits:12.8%
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL, FOAM.
Fire Fighting Procedures:WEAR NIOSH APPRVD SCBA & FULL PROT EQUIP .
    WATER SPRAY MAY BE INEFTIVE. IF WATER IS USED, FOG NOZZS ARE PREF.
    WATER MAY BE USED TO COOL CLSD (SUPP DATA)
Unusual Fire/Explosion Hazard:KEEP CNTNRS TIGHTLY CLSD. ISOLATE FROM
    HEAT, ELEC EQUIP, SPKS & OPEN FLAME. CLSD CNTNRS MAY EXPLODE WHEN
    EXPOSED TO EXTREME HEAT. APPLICATN TO HOT SURFS(SUPDAT)

==================  Accidental Release Measures  ==================

Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION. VENTILATE AND
    REMOVE WITH INERT ABSORBENT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:USE ONLY W/ADEQ VENT. AVOID BRTHG VAP
    & SPRAY MIST. AVOID CONT W/SKIN & EYES. CONTENTS ARE EXTREMELY
    FLAM. KEEP AWAY FROM HEAT, SPKS & OPEN FLAME.
Other Precautions:VAPS WILL ACCUM READILY & MAY IGNITE EXPLOSIVELY.
    DURING USE & UNTIL ALL VAPS ARE GONE:KEEP AREA VENTD, DO NOT SMK,
    EXTING ALL FLAMES, PILOT LIGHTS & HEATERS, TURN OFF STOVES, ELEC
    TOOLS & APPLIANCES	& ANY OTHER IGNIT SOURCES. (ING 11)

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:IF PERSONAL EXPOSURE CANNOT BE CONTROLLED BELOW
    APPLICABLE LIMITS BY VENTILATION, WEAR A PROPERLY FITTED ORGANIC
    VAPOR/PARTICULATE RESPIRATOR APPROVED BY NIOSH FOR PROTECTION
    AGAINST MATERIALS IN HAZA RDOUS INGREDIENTS.
Ventilation:LOC EXHST PREF. GEN EXHST ACCEPTABLE IF EXPOS TO MATLS IN
    INGS IS MAINTAINED BELOW EXPOS LIMS. REFER TO OSHA (SUPDAT)
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:ANSI APPROVED EMERGENCY EYE WASH AND DELUGE
    SHOWER .
Work Hygienic Practices:WASH HANDS AFTER USING.
Supplemental Safety and Health
FIRE FIGHT PROC:CNTNRS TO PVNT PRESS BUILD-UP & POSS AUTOIGNIT/EXPLO
    WHEN EXPOSED TO EXTREME HEAT. EXPLO HAZ:REQS SPECIAL PRECS. DURING
    EMER CNDTNS OVEREXP TO DECOMP PRODS MAY CAUSE HLTH HAZ. SYMPS MA Y
    NOT BE IMMED APPARENT. OBTAIN MED ATTN. VENT:STDS 1910.94,
    1910.107, 1910.108.

==================  Physical/Chemical Properties  ==================

Boiling Pt:B.P. Text:<0F,<-18C
Vapor Pres:SEE INGS
Vapor Density:HVR/AIR
Spec Gravity:0.76
Evaporation Rate & Reference:FASTER THAN ETHER
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:92

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
NONE KNOWN.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:BY FIRE:CARBON DIOXIDE, CARBON
    MONOXIDE.

====================  Disposal Considerations  ====================

Waste Disposal Methods:WASTE MAY BE HAZ AS DEFINED UNDER RESOURCE
    CONSERVATION & RECOVERY ACT (RCRA) 40 CFR 261. WASTE MUST BE TESTED
    FOR IGNITABILITY TO DETERM APPLIC EPA HAZ WASTE #'S. DO NOT INCIN.
    DEPRESS CNTNR. DISP OF  I/A/W FED, STATE & LOC REGS REGARDING
    POLLUTION.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.