RECTORSEAL CORP -- T PLUS 2 -- 8030-00N028002
=====================  Product Identification  =====================

Product ID:T PLUS 2
MSDS Date:01/15/1991
FSC:8030
NIIN:00N028002
=== Responsible Party ===
Company Name:RECTORSEAL CORP
Address:2830 PRODUCE ROW
City:HOUSTON
State:TX
ZIP:77023-5822
Country:US
Info Phone Num:713-928-6423
Emergency Phone Num:713-928-6423
CAGE:60150
=== Contractor Identification ===
Company Name:THE RECTORSEAL CORPORATION
Address:2601 SPENWICK
Box:City:HOUSTON
State:TX
ZIP:77055
Country:US
Phone:800-231-3345
CAGE:60150

=============  Composition/Information on Ingredients  =============

Ingred Name:NON HAZARDOUS INGREDIENTS

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:NO	Skin:YES  Ingestion:YES
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:MAY PRODUCE SLIGHT TO MODERATE SKIN
    AND EYE IRRITATION. CHRONIC EFFECTS ARE NOT DETERMINED.
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:EYES: IRRITATION, WATERING MAY OCCUR. INHAL:
    INHAL OF THERMAL DECOMP BYPRODUCTS FROM BURING MAY CAUSE "POLYMER
    FUME FEVER" CHARACTERIZED BY FEVER, COUGH, MALAISE. INGEST: MAY
    CAUSE NAUSEA AND VOMITING . NOT EXPECTED TO PRODUCE TOXIC
    EFFECTSUNLESS LARGE AMOUNTS ARE INGESTED. SKIN: IRRITATION MAY
    OCCUR.
Medical Cond Aggravated by Exposure:NOT DETERMINED.

=======================  First Aid Measures  =======================

First Aid:EYES: FLUSH W/LARGE AMTS OF WATER FOR AT LEAST 15 MIN. SEEK
    IMMED MEDICAL ATTENTION. INHAL: REMOVE TO FRESH AIR. IF IRRIT
    PERSISTS, SEEK IMMED MEDICAL ATTN. INGEST: GIVE LG AMTS OF WATER.
    INDUCE VOMIT ING. IF UNCON, DO NOT GIVE ANYTHING BY MOUTH OR
    ATTEMPT TO INDUCE VOMITING. SEEK IMMEDIATE MEDICAL ATTENTION. SKIN:
    WASH WITH SOAP AND WATER. IF IRRITATION OCCURS, SEEK MEDICAL
    ATTENTION.

=====================  Fire Fighting Measures  =====================

Flash Point Method:TCC
Flash Point:302F,150C
Extinguishing Media:FOAM, DRY CHEMICAL, CO*2, OR WATER FOG.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
    PROTECTIVE EQUIPMENT . EVACUATE AREA. TOXIC DECOMPOSITION PRODUCTS
    POSSIBLE.
Unusual Fire/Explosion Hazard:HEAT MAY BUILD UP PRESSURE AND RUPTURE
    CLOSED CONTAINERS. ABOVE 500F (260C), THE FUMES ARE ACUTELY TOXIC.

==================  Accidental Release Measures  ==================

Spill Release Procedures:WIPE UP SPILLS TO PREVENT FOOTING HAZARD.
    AVOID FLUSHING INTO SEWERS, DRAINS, WATERWAYS AND SOIL. WEAR
    PROTECTIVE CLOTHING DURING CLEANUP.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:KEEP CONTAINER CLOSED WHEN NOT IN USE.
    DO NOT STORE NEAR HEAT, SPARKS, OR OPEN FLAMES.
Other Precautions:AVOID PROLONGED OR REPEATED CONTACT WITH SKIN OR
    CLOTHING. EMPTY CONTAINERS MAY CONTAIN RESIDUES; TREAT AS IF FULL
    AND OBSERVE ALL PRODUCT PRECAUTIONS. DO NOT REUSE EMPTY CONTAINERS.
    KEEP OUT OF REACH  OF CHILDREN.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:NORMALLY NOT REQUIRED. NIOSH/MSHA APPROVED
    RESPIRATOR APPROPRIATE FOR EXPOSURE OF CONCERN .
Ventilation:LOCAL EXHAUST: ACCEPTABLE. MECHANICAL (GENERAL):
    ACCEPTABLE.
Protective Gloves:NON-PERMEABLE GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:COVERALLS RECOMMENDED.
Work Hygienic Practices:WHERE USE CAN RESULT IN SKIN CONT, WASH EXPOS
    AREAS THORO BEFORE EATING/DRINKING/SMOKING/LEAVING WORK AREA. (SUPP
    DATA)
Supplemental Safety and Health
HAZ DECOMP PROD: CARBONYL FLUORIDE ARE EVOLVED UPON BURNING. HYGIENE
    PRACT: LAUNDER CONTAMINATED CLOTHING BEFORE REUSE.

==================  Physical/Chemical Properties  ==================

HCC:N1
Vapor Pres:<1 @ 77F
Spec Gravity:1.32 (H*2O=1)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:WHITE PASTE; SLIGHT ODOR.

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
GASEOUS OXYGEN, STRONG OXIDIZING MATERIALS, MOLTEN ALKALI METALS.
Stability Condition to Avoid:HEAT, SPARKS, OPEN FLAMES AND STRONG
    OXIDIZING CONDITIONS. TEMPERATURES ABOVE 500F (200C).
Hazardous Decomposition Products:CO, CO*2 & FRAGMENTED HYDROCARBONS.
    TETRAFLUOROETHYLENE, HEXAFLUOROPROPYLENE, PERFLUOROISOBUTYLENE &
    (SUPP DATA)

====================  Disposal Considerations  ====================

Waste Disposal Methods:DISPOSE OF CLEANUP MATERIALS AND LIQUID WASTE IN
    CONTROLLED INCINERATION FACILITIES I/A/W ALL LOCAL, STATE AND
    FEDERAL REGULATIONS.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.