RECTORSEAL CORP -- T PLUS 2 -- 8030-00N028002
===================== Product Identification ===================== Product ID:T PLUS 2 MSDS Date:01/15/1991 FSC:8030 NIIN:00N028002 === Responsible Party === Company Name:RECTORSEAL CORP Address:2830 PRODUCE ROW City:HOUSTON State:TX ZIP:77023-5822 Country:US Info Phone Num:713-928-6423 Emergency Phone Num:713-928-6423 CAGE:60150 === Contractor Identification === Company Name:THE RECTORSEAL CORPORATION Address:2601 SPENWICK Box:City:HOUSTON State:TX ZIP:77055 Country:US Phone:800-231-3345 CAGE:60150 ============= Composition/Information on Ingredients ============= Ingred Name:NON HAZARDOUS INGREDIENTS ===================== Hazards Identification ===================== LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER. Routes of Entry: Inhalation:NO Skin:YES Ingestion:YES Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO Health Hazards Acute and Chronic:MAY PRODUCE SLIGHT TO MODERATE SKIN AND EYE IRRITATION. CHRONIC EFFECTS ARE NOT DETERMINED. Explanation of Carcinogenicity:NOT RELEVANT Effects of Overexposure:EYES: IRRITATION, WATERING MAY OCCUR. INHAL: INHAL OF THERMAL DECOMP BYPRODUCTS FROM BURING MAY CAUSE "POLYMER FUME FEVER" CHARACTERIZED BY FEVER, COUGH, MALAISE. INGEST: MAY CAUSE NAUSEA AND VOMITING . NOT EXPECTED TO PRODUCE TOXIC EFFECTSUNLESS LARGE AMOUNTS ARE INGESTED. SKIN: IRRITATION MAY OCCUR. Medical Cond Aggravated by Exposure:NOT DETERMINED. ======================= First Aid Measures ======================= First Aid:EYES: FLUSH W/LARGE AMTS OF WATER FOR AT LEAST 15 MIN. SEEK IMMED MEDICAL ATTENTION. INHAL: REMOVE TO FRESH AIR. IF IRRIT PERSISTS, SEEK IMMED MEDICAL ATTN. INGEST: GIVE LG AMTS OF WATER. INDUCE VOMIT ING. IF UNCON, DO NOT GIVE ANYTHING BY MOUTH OR ATTEMPT TO INDUCE VOMITING. SEEK IMMEDIATE MEDICAL ATTENTION. SKIN: WASH WITH SOAP AND WATER. IF IRRITATION OCCURS, SEEK MEDICAL ATTENTION. ===================== Fire Fighting Measures ===================== Flash Point Method:TCC Flash Point:302F,150C Extinguishing Media:FOAM, DRY CHEMICAL, CO*2, OR WATER FOG. Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL PROTECTIVE EQUIPMENT . EVACUATE AREA. TOXIC DECOMPOSITION PRODUCTS POSSIBLE. Unusual Fire/Explosion Hazard:HEAT MAY BUILD UP PRESSURE AND RUPTURE CLOSED CONTAINERS. ABOVE 500F (260C), THE FUMES ARE ACUTELY TOXIC. ================== Accidental Release Measures ================== Spill Release Procedures:WIPE UP SPILLS TO PREVENT FOOTING HAZARD. AVOID FLUSHING INTO SEWERS, DRAINS, WATERWAYS AND SOIL. WEAR PROTECTIVE CLOTHING DURING CLEANUP. Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER. ====================== Handling and Storage ====================== Handling and Storage Precautions:KEEP CONTAINER CLOSED WHEN NOT IN USE. DO NOT STORE NEAR HEAT, SPARKS, OR OPEN FLAMES. Other Precautions:AVOID PROLONGED OR REPEATED CONTACT WITH SKIN OR CLOTHING. EMPTY CONTAINERS MAY CONTAIN RESIDUES; TREAT AS IF FULL AND OBSERVE ALL PRODUCT PRECAUTIONS. DO NOT REUSE EMPTY CONTAINERS. KEEP OUT OF REACH OF CHILDREN. ============= Exposure Controls/Personal Protection ============= Respiratory Protection:NORMALLY NOT REQUIRED. NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR EXPOSURE OF CONCERN . Ventilation:LOCAL EXHAUST: ACCEPTABLE. MECHANICAL (GENERAL): ACCEPTABLE. Protective Gloves:NON-PERMEABLE GLOVES. Eye Protection:CHEMICAL WORKERS GOGGLES . Other Protective Equipment:COVERALLS RECOMMENDED. Work Hygienic Practices:WHERE USE CAN RESULT IN SKIN CONT, WASH EXPOS AREAS THORO BEFORE EATING/DRINKING/SMOKING/LEAVING WORK AREA. (SUPP DATA) Supplemental Safety and Health HAZ DECOMP PROD: CARBONYL FLUORIDE ARE EVOLVED UPON BURNING. HYGIENE PRACT: LAUNDER CONTAMINATED CLOTHING BEFORE REUSE. ================== Physical/Chemical Properties ================== HCC:N1 Vapor Pres:<1 @ 77F Spec Gravity:1.32 (H*2O=1) Solubility in Water:NEGLIGIBLE Appearance and Odor:WHITE PASTE; SLIGHT ODOR. ================= Stability and Reactivity Data ================= Stability Indicator/Materials to Avoid:YES GASEOUS OXYGEN, STRONG OXIDIZING MATERIALS, MOLTEN ALKALI METALS. Stability Condition to Avoid:HEAT, SPARKS, OPEN FLAMES AND STRONG OXIDIZING CONDITIONS. TEMPERATURES ABOVE 500F (200C). Hazardous Decomposition Products:CO, CO*2 & FRAGMENTED HYDROCARBONS. TETRAFLUOROETHYLENE, HEXAFLUOROPROPYLENE, PERFLUOROISOBUTYLENE & (SUPP DATA) ==================== Disposal Considerations ==================== Waste Disposal Methods:DISPOSE OF CLEANUP MATERIALS AND LIQUID WASTE IN CONTROLLED INCINERATION FACILITIES I/A/W ALL LOCAL, STATE AND FEDERAL REGULATIONS. Disclaimer (provided with this information by the compiling agencies): This information is formulated for use by elements of the Department of Defense. The United States of America in no manner whatsoever, expressly or implied, warrants this information to be accurate and disclaims all liability for its use. Any person utilizing this document should seek competent professional advice to verify and assume responsibility for the suitability of this information to their particular situation.